Slow closing check valve
+
  • Slow closing check valve

Slow closing check valve

Model:

HY741X

Specifications:

DN20-DN800

Applicable temperature:

0~ 80

Applicable medium:

Water, clean water


Return to List Contact Us
  • Product Description
  • Detailed parameters
  • Slow closing check valve, also known as check valve, its role is to prevent the medium in the pipeline back. Opening and closing parts by the medium flow and power to open or close on their own to prevent the medium back flow of the valve. The check valve belongs to the automatic valve category, mainly used for the medium one-way flow of the pipeline, only allows the medium to flow in one direction to prevent accidents. This type of valve in the pipeline should generally be installed horizontally.

    Slow closing check valve is composed of main valve 2, check valve 5, needle valve 1, ball valve 3, pressure valve table 4, etc. Slowly closing check valve has the function of opening and closing speed regulation and backstop. The valve installation can effectively control the water pump to automatically adjust to the best opening and closing speed when starting and stopping rotation. Generally divided into two categories of diaphragm type and piston type, the factory production of slow-closing type check valve diameter in the DN500mm below the diaphragm type, the diameter of the DN600mm above the piston type, the principle of action of the two is similar. It is widely used in industrial water supply and high-rise building water supply system directly by water pump to reduce the water cone and water hammer phenomenon, and achieve the effect of safe closing.

    Description of technical advantages of slow closing check valve;

    The structure length is short, and its structure length is only 1/4~1/8 of the traditional flange check valve.

    2, small size, light weight, its weight is only 1/4~1/20 of the traditional flange check valve.

    3. The valve flap closes quickly and the water hammer pressure is small.

    4. Horizontal or vertical pipes can be used, easy to install.

    5, smooth flow, small fluid resistance.

    6, sensitive action, good sealing performance.

    7, the valve stroke is short, close the valve impact force is small.

    8, the overall structure, simple and compact, beautiful appearance.

    9. Long service life and high reliability.

    Maintenance and maintenance requirements for slow closing check valves;

    1. The valve should be stored in a dry and ventilated room to prevent moisture, rain and rust.

    2. The opening and closing parts should be in the closing device during storage and transportation, and the following work should be done:

    a. The disc should be fixed in the open position

    B. the inner openings at both ends of the diameter shall be blocked with foam board, and the ports shall be blocked with stuffy covers to prevent dust and rust, so as to keep the passage clean and the end face smooth;

    c. The cylinder part shall be properly packaged, protected, shockproof and anti-collision;

    d. The valve should be placed smoothly, pneumatic drive device upward, shall not be squeezed each other.

    3, long-term placement should be regularly checked. Every three months, check the dirt and rust on the two channels and the sealing surface, and check the protection status of the welding joint. After wiping the dirt and rust, apply anti-rust oil again for protection.

    Slow closing check valve is installed in the high-rise building water supply system and other water supply system of the pump outlet, to prevent the media back, water hammer and water hammer phenomenon of intelligent valve. The valve has three functions of electric valve, check valve and water hammer eliminator, which can effectively improve the safety and reliability of the water supply system, and integrate the technical principles of slow opening, fast closing and slow closing to eliminate water hammer, so as to prevent the generation of water hammer and stop pump. Just operate the pump motor opening and closing button, the valve can be automatically opened and closed according to the pump operating procedures, with large flow and small pressure loss.


    Warm tips:

    All text, data, and images in this article are for reference only. Need to see more pairsClip butterfly check valveFor details of performance parameters, structural size parameters, prices, etc., or for high-quality printed samples, pleaseContact Us


     

  • Outline and connection dimension of slow closing check valve

    DN L A A1 H H1 F
    20 180 282 200 172 106 116
    25 180 282 200 172 106 116
    32 180 282 200 172 106 116
    40 240 320 210 265 210 170
    50 240 320 210 265 210 170
    65 250 330 215 310 215 180
    80 285 350 220 350 245 210
    100 360 410 230 460 305 275
    125 400 420 245 520 365 310
    150 455 430 260 570 415 355
    200 585 440 280 695 510 460
    250 650 450 300 780 560 500
    300 800 460 320 905 658 580
    350 860 470 340 1025 696 640
    400 960 480 360 1080 735 715
    450 1075 530 395 1030 210 780
    500 1075 580 420 1135 665 830
    600 1230 600 445 1270 725 920
    700 1650 730 495 1460 865 980
    800 1750 830 530 1640 925 1050